There has been increasing necessity of more precise prediction and measurements

of aviation radiation in Korea. For our air crew and passengers’ radiation safety, we

develop our own radiation prediction model of KREAM. In this paper, we validate the

KREAM model based on comparison with Liulin observations. During early three months of

this year, we perform total 25 experiments to measure aviation radiation exposure using

Liulin-6K in commercial flights. We found that KREAM’s result is very well consistent

with Liulin observation in general. NAIRAS shows mostly higher results than Liulin

observation, while CARI-6M shows generally lower results than the observations. The

percent error of KREAM compared with Liulin observation is 10.95%. In contrast, the

error for NAIRAS is 43.38% and 22.03% for CARI-6M. We found that the increase of the

altitude might cause sudden increase in radiation exposure, especially for the polar

route. As more comprehensive and complete analysis is required to validate KREAM’s

reliability to use for the public service, we plan to expand these radiation

measurements with Liulin and Tissue Equivalent Proportional Counter (TEPC) in the near

future.