Monitoring ammonia slip from large-scale selective catalytic reduction (SCR) systems in combined heat and power generation applications with field effect gas sensors
Monitoring ammonia slip from large-scale selective catalytic reduction (SCR) systems in combined heat and power generation applications with field effect gas sensors
Lida Khajavizadeh,Mike Andersson
2023 · DOI: 10.5194/jsss-12-235-2023
Journal of Sensors and Sensor Systems · 2 Citations
Abstract
Abstract. Following tightened regulations, selective catalytic reduction (SCR) of nitrogen oxides (NOx) by ammonia (NH3) has over
the last couple of decades found wider adoption as a means of reducingNOx emissions from e.g. power production and district heating plants. As in the SCR process NH3 injected into the flue gas reactswith and reduces NOx to nitrogen (N2) and water (H2O) on thesurface of a specific catalyst, the NH3 injection has to be dynamically adjusted to match both instant and long-term variations in flue gas nitrogenoxide concentration in order to minimize NOx and NH3 emissions. One possibility of realizing such NH3 dosing control would be the real-time monitoring and feedback of downstream flue gas NOx andNH3 concentrations to the NH3 injection control unit. In thisstudy the sensing characteristics and performance of SiC-based Metal Oxide Semiconductor FieldEffect Transistor (MOSFET)sensors with a structurally tailored gas-sensitive gate contact of iridium(Ir) for in situ NH3 monitoring downstream from the SCR catalyst in acombined heat and power (CHP) plant have therefore been investigated andevaluated. The sensor's NH3 sensitivity and selectivity as well as thecross-sensitivity to common flue gas components – oxygen (O2), watervapour (H2O), nitric oxide (NO), nitrogen dioxide (NO2), carbonmonoxide (CO), and a model hydrocarbon, ethene (C2H4) – werethereby investigated for relevant concentration ranges under controlledconditions in the laboratory. While, at the prescribed sensor operationtemperature of 300 ∘C, the influence of H2O, CO, andC2H4 on the sensor's NH3 concentration reading could beregarded as practically insignificant, a moderate cross-sensitivity was observed betweenNH3 and NO2 and, to a lesser extent, between NH3 / NO and NH3 / O2. As the NOx concentration downstream from theSCR catalyst under normal SCR and power plant operation is expected to beconsiderably smaller than the NH3 concentration whenever anyappreciable ammonia slip occurs, the observed NH3 / NOxcross-sensitivities may, however, be of less practical significance forammonia monitoring in real flue gases downstream from the SCR catalyst.Furthermore, if required, the small influence of O2 concentrationvariations on the sensor reading may also be compensated for by utilizingthe signal from a commercially available oxygen sensor. Judging from in situ measurements performed in a combined heat and power plant, the structurally tailored Ir gate field effect sensors also exhibit good NH3 sensitivity over the relevant 0–40 ppm range when directly exposed to real flue gases, offering an accuracy of ±3 ppm as well as low sensor signal drift, the latter most likely to further improve with regular zero-point calibration and thereby make the Ir gate MOSFET ammonia sensor a promising alternative for cost-efficient real-time ammonia slip monitoring or SCR system control in heat and/or power production plants.