Complexity of EEG Dynamics for Early Diagnosis of Alzheimer's Disease Using Permutation Entropy Neuromarker

Mesut Şeker,Yağmur Özbek,G. Yener,M. S. Özerdem

2021 · DOI: 10.1016/j.cmpb.2021.106116
103 Citations

TLDR

This nonlinear EEG methodology study contributes to literature with high discrimination rates for identification of AD and PE is recommended as a practical diagnostic neuro-marker for AD studies.

Abstract

BACKGROUND AND OBJECTIVE

Electroencephalogram (EEG) is one of the most demanded screening tools that investigates the effects of Alzheimer's Disease (AD) on human brain. Identification of AD in early stage gives rise to efficient treatment in dementia. Mild Cognitive Impairment (MCI) is considered as a conversion stage. Reducing EEG complexity can be used as a marker to detect AD. The aim of this study is to develop a 3-way diagnostic classification using EEG complexity in the detection of MCI/AD in clinical practice. This study also investigates the effects of different eyes states, i.e. eyes-open, eyes-closed on classification performance.

METHODS

EEG recordings from 85 AD, 85 MCI subjects, and 85 Healthy Controls with eyes-open and eyes- closed are analyzed. Permutation Entropy (PE) values are computed from frontal, central, parietal, temporal, and occipital regions for each EEG epoch. Distribution of PE values are visualized to observe discrimination of MCI/AD with HC. Visual investigations are combined with statistical analysis using ANOVA to determine whether groups are significant or not. Multinomial Logistic Regression model is applied to feature sets in order to classify participants individually.

RESULTS

Distribution of measured PE shows that EEG complexity is lower in AD and higher in HC group. MCI group is observed as an intermediate form due to heterogeneous values. Results from 3-way classification indicate that F1-scores and rates of sensitivity and specificity achieve the highest overall discrimination rates reaching up to 100% for at TP8 for eyes-closed condition; and C3, C4, T8, O2 electrodes for eyes-open condition. Classification of HC from both patient groups is achieved best. Eyes-open state increases discrimination of MCI and AD.

CONCLUSIONS

This nonlinear EEG methodology study contributes to literature with high discrimination rates for identification of AD. PE is recommended as a practical diagnostic neuro-marker for AD studies. Resting state EEG at eyes-open condition can be more advantageous over eyes-closed EEG recordings for diagnosis of AD.