Colour Stability of Veneering Composites after Accelerated Aging
Colour Stability of Veneering Composites after Accelerated Aging
Triantafillos Papadopoulos,A. Sarafianou,A. Hatzikyriakos
TLDR
Colour changes were found to be within accepted values of perceptibility and clinical acceptance after accelerated aging, and no statistically significant differences were found in ΔL*, Δa*, Δb* and ΔE among the materials tested.
Abstract
Objectives: To investigate the colour stability of four indirect composite restorative materials after accelerated aging. Methods: Four indirect composites (Gradia, Signum+, HFO and Adoro) were used. For each material, six specimens were prepared and subjected to accelerated aging (Suntest CPS+, Atlas, Chicago, IL, USA) according to ISO 7491. A Dr. Lange Microcolor Data Station colorimeter (Braive Instruments, Liege, Belgium) was used to measure specimen colour before and after aging. Measurements were performed according to the CIE Lab* system, and the mean L*, a* and b* values for each material were calculated. The equation ΔE = [(ΔL*)2 + (Δa*)2 + (Δb*)2]1/2 was used to measure the total colour change (ΔE), where ΔL*, Δa* and Δb* are the differences in the respective values before and after aging. One-way ANOVA were used to determine statistically significant differences in ΔL*, Δa*, Δb* and ΔE. Results: No statistically significant differences were found in ΔL*, Δa*, Δb* and ΔE among the materials tested (PΔL*=.063; PΔa*=.521; PΔb*=.984 and PΔE=.408). After aging, Gradia specimens showed an increase in lightness (ΔL*=0.36) and a green-yellow shift (Δa*=−1.18, Δb*=0.6), while Signum+ specimens exhibited an increase in lightness (ΔL*=0.5) and a green-blue shift (Δa*=−0.9, Δb*=−0.45). HFO specimens exhibited an increase in lightness (ΔL*=0.75) and a green-yellow shift (Δa*=−1.3, Δb*=0.06), and Adoro specimens exhibited an increase in lightness (ΔL*=2.07) and a green-yellow shift (Δa*=−1.3, Δb*=0.68). Conclusions: Colour changes were found to be within accepted values of perceptibility and clinical acceptance after accelerated aging, and no statistically significant differences were found in ΔL*, Δa*, Δb* and ΔE among the materials tested.